Designing acoustic-electric strain-gauge converters for sensitive diaphragm elements

1Chernyak, MG, 2Kovalenko, TV
1Interdisciplinary Research Institute for Problems in Mechanics Rhythm, National Technical University of Ukraine «Igor Sikorsky Kyiv polytechnic institute», Kyiv, Ukraine
2State Space Agency of Ukraine, Kyiv, Ukraine
Kosm. nauka tehnol. 1998, 4 ;(1):60–63
https://doi.org/10.15407/knit1998.01.060
Publication Language: Russian
Abstract: 
Analytical expressions and nomograms, are obtained to estimate the sensitivity of differential acoustic-electric measuring pressure converter with an error no more than 5 % and to choose such an arrangement of strain-gauge converters on its sensitive diaphragm element that would ensure an additive temperature error of the measuring pressure converter less than 10-4 К-1.
Keywords: acoustic-electric strain-gauge converters, space instruments, temperature error
References: 
1.  Birger I. A., Mavliutov R. R. Strength of Materials [Soprotivlenie materialov], 380 p. (Nauka, Moscow, 1986) [in Russian].
2.  Pavlovskij M. A, Lopushenko V. K., Chernyak N. G., Kondratenko N. G. Strain, temperature and gyroscopic effects in oscillators, surface acoustic wave. Mechanics of gyroscopic systems, Is. 9, 50—56 (1990) [in Russian].
3.  Frantsevich I. N., Voronov F. F., Bakuta S. A. Elastic constants and modules of elasticity of metals and nonmetals: Handbook, 190 p. (Naukova Dumka, Kiev, 1982) [in Russian].
4.  Rokhlin S. I., Korndlit L., Gorodetsky G. Surfase acoustic wave pressure transdusers and accelerometers. Prog. Aerospace Sci., 21, 1—31 (1984).
https://doi.org/10.1016/0376-0421(84)90002-2